1MKW/2MWH Containerized ESS Exporter | Scalable & High-Cycle BESS

Product Features

  • Highly integrated design, easy for transportation, installation and maintenance.
  • Real-time status monitoring and fault recording functions.
  • Intelligent modular design with CTP (Cell to Pack) technology.
  • Supports parallel connection for easy system expansion.
  • Multi-level battery protection system and HFC-227ea fire suppression system.
  • Customizable cooling options: liquid cooling and air cooling.
  • Long cycle life: over 6,000 cycles while maintaining 70% SOH.
  • Durable for more than 15 years with daily charging.
  • Suitable for renewable energy grid connection, grid stabilization, industrial energy management, commercial use, remote areas, etc.

Product Description

Battery Capacity

2010.6kWh

3360Ah / 598.4V LiFePO4 battery bank using CTP (Cell to Pack) technology.

Rated Power

1MW

Peak power 1.1MW. AC output 400V (−20% ~ +15%).

Container Form Factor

40ft

12192 × 2438 × 2896 mm, 25800 kg.

Cycle Life

6000+ cycles

Over 6000 cycles while maintaining 70% SOH — more than 15 years with daily charging.

IEC 62933
UN38.3
MSDS
RoHS 2.0
HFC-227ea fire suppression
4G remote monitoring
H098-2MWh · containerized series 500kWh / 1MWh / 2MWh / 3MWh
OEM / ODM customization for EPC and distributors

H098 2MWh containerized battery energy storage system in a 40ft container
H098 1MW / 2010.6kWh containerized battery energy storage system (40ft)

Overview

2MWh in a 40-foot container, with CTP technology and fire suppression

The 2MWh containerized energy storage system is a highly integrated, intelligent modular solution for commercial and industrial energy storage. It uses CTP (Cell to Pack) technology with a multi-level battery protection system and an HFC-227ea fire suppression system, and supports parallel connection for easy system expansion. Cooling can be specified as liquid cooling or air cooling.

H098 2MWh containerized energy storage system: system overview, direct comparison with 500kWh and application scenarios
H098 2MWh containerized ESS at a glance — 4× the capacity of the 500kWh container, same standard footprint

Highly integrated, easy to transport

Battery packs, PCS, BMS, EMS, fire suppression and thermal management all sit inside one 40ft container — easy for transportation, installation and maintenance.

Standard shipping container footprint

Multi-level battery protection

Layered battery protection system plus an integrated HFC-227ea fire suppression system, with real-time status monitoring and fault recording.

Full protection chain from cell to system level

CTP (Cell to Pack) modular design

Intelligent modular architecture that reduces parts and connections while making maintenance and replacement simpler.

Supports parallel connection for system expansion

Liquid cooling or air cooling

Cooling can be specified to suit the site: liquid cooling for uniform temperature control, or air cooling for simpler maintenance.

Choose to match climate and project requirements

Long service life

Over 6,000 cycles while maintaining 70% SOH, and durable for more than 15 years with daily charging.

Lower lifetime cost per delivered kWh

Remote monitoring & fault recording

Real-time status monitoring and historical fault records over 4G, with RS485 / CAN on the local bus.

Suitable for renewable-energy grid connection

System Topology

How the system connects

The container sits at the center of your site’s power system: solar, grid and diesel generation feed it, and it serves your loads while reporting everything to the cloud.

01

Solar input (PV modules)

Ground-mount or rooftop PV feeds the container. Excess solar generation is stored instead of curtailed, and released when it is worth more.

02

Grid connection via electricity meter

The utility grid charges the battery bank through the electricity meter at off-peak tariff. AC output 400V (−20% ~ +15%), 1444A rated current.

03

Diesel generator hybrid

Existing diesel gensets keep running as backup — the BESS cuts their running hours and fuel burn, and covers loads while generators start.

04

Loads & cloud platform

Factory and mall loads are served around the clock, while the EMS reports operating data to the cloud platform over 4G for remote monitoring.

2MWh solar container system topology with PV modules, power grid, diesel generators, loads and cloud platform
Solar container system topology — PV, grid and genset in; factory, mall and cloud out

The whole flow is automatic: the energy management system decides when to charge, when to discharge and when to hold reserve capacity, so your facility always runs on the cheapest available power.

What’s Inside

What is inside the 2MWh container

A 40ft container integrating the complete storage and conversion chain with CTP battery architecture and an integrated fire suppression system.

LiFePO4 battery packs (CTP)

3360Ah / 598.4V battery bank rated 2010.6kWh, built with Cell to Pack technology.

Multi-level battery protection

Layered battery protection system with real-time monitoring and fault recording.

PCS power conversion system

Rated 1MW (peak 1.1MW), 1444A rated / 1588A maximum AC current, supporting parallel connection.

EMS energy management system

Schedules charge and discharge and reports to the cloud platform for remote control.

HFC-227ea fire suppression

Integrated clean-agent fire suppression system inside the container.

Thermal management

Liquid cooling or air cooling, selected to match the site climate and project requirement.

Inside the H098 2MWh container: battery racks, PCS, transformer, air passage and fire pipeline
Inside the 2MWh container — battery racks, PCS, transformer, air passage and fire pipeline, all factory-installed

Specifications

H098-2MWh specifications

Complete technical parameters for the 1MW / 2010.6kWh container. Need a stamped datasheet for tender submission? Request it via the form at the bottom of this page.

ItemH098-2MWh
System
Product ModelH098-2MWh
Battery Capacity3360Ah / 598.4V (2010.6kWh)
Rated Power1 MW
Peak Power1.1 MW
Battery TypeLiFePO4 (Lithium Iron Phosphate)
Battery Cycle LifeOver 6000 cycles
Electrical
Battery Voltage Range467.5–682.5 V
AC Output Voltage400V (−20% ~ +15%)
AC Rated Current1444A
Max AC Output Current1588A
Communication ProtocolRS485 / CAN
Wireless Communication4G communication supported
Mechanical & Environment
Dimensions (L×W×H)12192×2438×2896 mm (40ft container)
Weight25800 kg
Discharge Temperature−20 °C ~ 50 °C
Charging Temperature Range−5 °C ~ 50 °C
Storage TemperatureRecommended 0 °C ~ 45 °C
Protection & Certification
System ProtectionOver-temperature, over-voltage, over-current, over-charge, over-discharge, load short-circuit and overload protection
Fire SuppressionHFC-227ea clean-agent system
Certification StandardsIEC, UN38.3, MSDS, RoHS
H098 2MWh BESS container external dimensions 12192 x 2438 x 2896 mm
External dimensions: 12192 × 2438 × 2896 mm, standard 40ft high-cube container

Specifications are subject to the documents shipped with each unit. Certifications can be provided on request to meet specific regional grid and project requirements.

Applications

Where the 2MWh container is deployed

Utility-scale adjacent storage for industrial users and renewable plants that need megawatt-hour capacity in a standard container footprint.

Renewable energy grid connection

Smooth renewable output and shift generation to peak-price hours.

Large industrial demand management

Cut demand charges and relieve transformer capacity pressure.

Solar and wind farms

Pair with PV or wind generation to firm the output and raise self-consumption.

EV charging hubs

High-power charging buffering without oversized grid connections.

Mining and remote industry

Reliable power for sites with weak or intermittent grid supply.

Commercial parks & campuses

Centralized storage across multiple buildings and tenants.

Photovoltaic plus energy storage project site photos and performance: annual clean energy generation, CO2 reduction, peak shaving and backup power
Real project site — Huada containerized ESS running alongside a ground-mount PV plant

Packing & Delivery

Container delivery and commissioning support

The container leaves the factory fully pre-tested. On site it needs a prepared foundation, cable connection and grid tie — our team supports acceptance.

01

Requirements & selection

Capacity, grid connection and site conditions confirmed against your load profile and local tariff structure.

Scheduled per project

02

Production & configuration

Built to the confirmed configuration, with cell and module batch records kept on file.

Scheduled per project

03

Full-function testing

Every unit completes full-function FAT testing before shipment, with multiple QA re-tests.

Completed pre-shipment

04

Reinforced export packing

Reinforced packing plus standard hoisting points, suited to sea and land transport.

Standard export packing

05

Shipping & arrival

Shipping documents and parameter sheets travel with the unit; we support customs clearance and site acceptance.

Per shipping schedule

06

Installation, grid tie & O&M

On-site wiring and grid connection, then onboarding to the cloud platform for remote monitoring.

Depends on site conditions

Photovoltaic plus energy storage real project case with Huada New Energy containerized BESS beside a ground-mount solar plant
Photovoltaic + energy storage project case — Huada containerized ESS in commercial operation

FAQ

Frequently asked questions

The questions we are asked most often about this containerized energy storage system.

What is the container size and weight?
It uses a 40ft container, 12192 × 2438 × 2896 mm, 25800 kg — the standard high-cube container envelope.
What are the onsite installation requirements?
The container arrives pre-assembled. On site you need a prepared foundation, cable connection and commissioning. It is highly integrated and easy to transport, install and maintain.
Is it liquid-cooled or air-cooled?
Both options are available — cooling can be specified as liquid cooling or air cooling to match your climate and project requirements.
How long will the batteries last?
Over 6,000 cycles while maintaining 70% SOH, and durable for more than 15 years with daily charging.
Does it support fire suppression and expansion?
Yes. It integrates an HFC-227ea clean-agent fire suppression system with a multi-level battery protection system, and supports parallel connection for system expansion.
Do you accept OEM and ODM orders?
Yes. Huada supports customized capacity, cabinet design and software functions, and can tailor parameters to your grid standards and project requirements.

Get a Quote

Tell us about your project

Share your site type, location and approximate load, and we will come back with a capacity recommendation and a quotation.








We normally reply within one business day. Your details are used only for this enquiry.

Who We Are

About Huada New Energy

Huada New Energy (Huizhou Huada Technology Co., Ltd.) is a professional energy storage manufacturer with a complete product portfolio — portable power stations, household energy storage systems and commercial & industrial (C&I) solutions. Starting from lead-acid battery production, we have grown into an advanced lithium technology manufacturer.

We are backed by multiple invention patents, utility model patents, design patents and High-Tech Enterprise certification. With a professional R&D team, modern production facilities and a global energy monitoring data center, we provide reliable OEM/ODM services for customers worldwide.

Lithium Technology

Advanced lithium battery manufacturer, upgraded from lead-acid production.

OEM / ODM

Reliable OEM/ODM services for customers worldwide.

Global Monitoring

Global energy monitoring data center for after-sales support.

Certified Quality

High-Tech Enterprise certification with a full patent portfolio.

Learn how we helped 100 top brands gain success.

Let's have a chat