Fire-Retardant Coating Material Test for Battery Safety

Table of Contents

Huada fire-retardant coating material test: a coated battery sample heated by an open flame with a temperature meter and a fire extinguisher on standby

At Huada New Energy, battery safety is tested, not just claimed. This case documents an in-house fire-retardant coating material test: a coating-treated battery sample is heated by an open flame on a laboratory bench, with a temperature meter monitoring the sample and a fire extinguisher kept on standby.

1. Test Setup

The test places a coated battery sample over a controlled open flame while temperature is recorded throughout the process. The setup lets our engineers observe how the fire-retardant coating responds to direct heat and flame exposure, and how the sample behaves under sustained heating.

2. Why It Matters for Energy Storage

Fire safety is a core part of battery system design. Materials that help slow heat transfer and flame spread can add a layer of protection to battery cells and modules. Observations from this material test feed into how we select and apply protective materials across Huada’s home, commercial and containerized energy storage products.

3. Coating Material & Third-Party Test Data

The coating used in this test is MARC-01, a fire-resistant coating supplied by Hunan Yingsuo Technology (TopMaterial). Huada applies it as one protective material in battery safety design. The figures below come from test reports commissioned by the coating supplier on the coating sample itself — they are not a certified fire rating for a finished Huada battery or system.

Test itemMethod / reportResult
Fire resistance (coated steel panel)Bunsen burner, 800–850 °C for 30 min — Report YJ2025060240No burn-through; back-face temperature below 300 °C throughout, peak 154.8 °C — Pass
Adhesion (cross-cut)GB/T 31586-2015 — Report EMT02R000171C01Grade 0 (requirement ≤ Grade 1) — Pass
RoHSEU 2011/65/EU + (EU) 2015/863 — Report A2260349272101001CCompliant

Test Photos

The images below are the original test photographs from report YJ2025060240, showing the coated steel panel before, during and after the 30-minute flame exposure. The English captions are retained from the report.

Before test - fire-exposed surface of the MARC-01 coated steel panel
Before test - non-fire-exposed (back) surface of the MARC-01 coated steel panel
During test - fire-exposed surface under an 800-850 C open flame
During test - non-fire-exposed (back) surface while the front face is heated
After test - fire-exposed surface showing the intumescent char layer
After test - non-fire-exposed (back) surface remained intact

These reports were issued for the coating material at the supplier’s request and are provided for reference only. They do not constitute a certification, fire-resistance rating, or compliance claim for Huada’s battery products.

Note: This page documents an internal material test for demonstration purposes. It is not a third-party certification, a formal fire-resistance rating, or a claim of compliance with any specific standard.

Awesome! Share to:

Learn how we helped 100 top brands gain success.

Let's have a chat